Basic Info

Model No.:  GDP200*S

Product Description Model NO.: GDP200*S Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Ordinary Wire: 100% Pure Copper Wire Engine: Perkin Brand, Cummins, Mtu, Deutz Is Optional Function: ATS/Amf, Open/Soundproof Is Optional Specification: IECBS 5000, IEC 34, CCC, CE, ISO9001, SGS HS Code: 8501620000 Installation Method: Fixed Cooling Method: Wind Cooling Speed: Speed Usage: Common Units Excitation Mode: AC Rotating Exciter Alternator: Stamford, Marathon, Engga Controller: Dse, Smartgen Is Optional Trademark: GODLIKE (OEM supported) Origin: Jiangdu, Jiangsu, China 160kw/200kVA Perkin Diesel Generator Set for Railway (GDP200*S)

Engine specification
1.20kw-1000kw Perkins engine
2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection
3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler
4. Machinery or electronic governing
5. Fuel injection pump
6. Electric motor starting system
7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner
8. Low discharge, and low fuel consumption

Alternator: Stamford
Option with: Marathon, Leroy somer,
A) three phase brushless Generator, self-excited, 4-pole, single bearing
B) AVR self-regulated, voltage regulation rate ≤ ± 1%
C) IP23 protection grade
D) Class H insulation
E) Radio interference restraining accords with stipulation of VDE0875-N and ISO8528
F) Moistureproof, sand-proof, dustproof, salt-proof and vibration-proof

Control system:
1. Automatic cutter which is suitable for the generator power
2. Turn on key
3. A device to measure the generators speed
4. Counter for measuring the Operating hours
5. Device to measure the current overload with a switched current
6. A device to measure the battery voltage
7. Voltmeter with a voltage exchanger
8. A device to measure the frequency
9. Thermostat to regulate the voltage
10. A device to measure the oil pressure
11. Alerting lamps indicating low and high temperature
12. Controller of the current increase and short circuit
13. Emergency stop button

Generator Set Model Code GDP200*S
Alternator Alternator Model Code UCI274H
Alternator Brand Stamford
Frequency(Hz) 50Hz
Rated Power(KW/KVA) 160KW200KVA
Standby Power(KW/KVA) 176KW/220KVA
Rated Voltage(V) 400/380V
Rated Current(A) 72A
Steady Voltage Regulation ≤ 1.0%
Transient Voltage Regulation ≤ +20%, -15% (60% In, cosφ =0.4 lag)
Adjustable Voltage Range 95-105% Un
Waveform Distortion at No-load ≤ 5% (Line Voltage)
Insulation Class H
Power Factor (cosφ ) 0.8
Engine Engine Model Code 1106A-70TAG4
Engine Brand Perkin
Speed(RPM) 1500
Bore X Stroke (mm) 102x120
Displacement (L) 3.9
Max Water Temperature 100C
100%Load Fuel Consumption (g/kw. h) 209
Governor Type Perkin Unique Pump with Electrical Fuel Control System (EFC)
Exhaust Back Pressure 10kPa (Maximum)
Lubrication Oil(L) 11
Generator Set Start Method Electric Start
Battery Voltage(V) 24
Output 3-Phase/4-Wire
Standard Altitude ≤ 1300mm, if above, 4% of rated power will descend per 300 meter
Ambient Temperature ≤ 40C, Well Ventilation, If above, 2% of rated power will descend per 11C
Silent type Size(MM) 4300*1430*2175
Packing Material Nude
Net Weight(kg)open type 4306
ATS& AMF: module functions 1. Low oil pressure shutdown.
2. High water temperature shutdown.
3. Over speed shut down.
4. Under voltage tripping.

UK Perkins configuration and technical data
50HZ, 3 Phase, 400/230V
No. GENSET
Model
OUTPUT POWER 
1500RPM 50HZ
Engine Model Alternator Model Cyl. Disp. Bore
*Stroke
Fuel Cons.
Prime
KVA
Prime
KW
Standby
KVA
Standby
KW
UK Perkins Godlike Stamford (nos) (L) (mm) (g/kw.h)
1 GDP9*S 9 7 10 8 403D-11G JDG164A BCI164A 3 1.1 77*81 248
2 GDP13*S 13 10 14 11 403D-15G JDG164C BCI164C 3 1.5 84*90 248
3 GDP20*S 20 16 22 18 404D-22G JDG184E BCI184E 4 2.2 84*100 233
4 GDP26*S 26 21 29 23 404D-22TG JDG184F BCI184F 4 2.2 84*100 246
5 GDP30*S 30 24 33 26 1103A-33G JDG184G BCI184G 3 3.3 105*127 211
6 GDP30*S 30 24 33 26 1103C-33G3 JDG184G BCI184G 3 3.3 105*127 242
7 GDP45*S 45 36 50 40 1103A-33TG1 JDG224C UCI224D 3 3.3 105*127 215
8 GDP45*S 45 36 50 40 1103C-33TG3 JDG224C UCI224D 3 3.3 105*127 217
9 GDP60*S 60 48 66 53 1103A-33TG2 JDG224D UCI224E 3 3.3 105*127 217
10 GDP60*S 60 48 66 53 1104C-44TG3 JDG224D UCI224E 4 4.4 105*127 219
11 GDP65*S 65 52 72 57 1104A-44TG1 JDG224E UCI224F 4 4.4 105*127 208
12 GDP80*S 80 64 88 70 1104A-44TG2 JDG224FC UCI224G 4 4.4 105*127 205
13 GDP80*S 80 64 88 70 1104C-44TAG1 JDG224FC UCI224G 4 4.4 105*127 211
14 GDP100*S 100 80 110 88 1104C-44TAG2 JDG274B UCI274C 4 4.4 105*127 205
15 GDP135*S 135 108 150 120 1006TAG JDG274D UCI274E 4 6.0 100*127 208
16 GDP135*S 135 108 150 120 1106C-E66TAG2 JDG274D UCI274E 6 6.0 100*127 206
17 GDP150*S 150 120 165 132 1006TAG2 JDG274EC UCI274F 6 6.0 100*127 206
18 GDP150*S 150 120 165 132 1106C-E66TAG3 JDG274EC UCI274F 6 6.0 105*127 209.4
19 GDP180*S 180 144 200 160 1106C-E66TAG4 JDG274F UCI274H 6 6.0 105*127 206.9
20 GDP208*S 208 166 228 182 1306C-E87TAG3 JDG274H UCI274J 6 8.7 116.6*135.9 207
21 GDP228*S 228 182 250 200 1306C-E87TAG4 JDG274H UCI274J 6 8.7 116.6*135.9 201
22 GDP235*S 235 188 258 207 1306C-E87TAG5 JDG274J UCI274K 6 8.7 116.6*135.9 203
23 GDP250*S 250 200 275 220 1306C-E87TAG6 JDG274J UCI274K 6 8.7 116.6*135.9 188
24 GDP300*S 300 240 330 264 2206A-E13TAG2 JDG314C HCI444D 6 12.5 130*157 196
25 GDP325*S 325 260 358 286 2206A-E13TAG2 JDG314DC HCI444ES 6 12.5 130*157 197
26 GDP350*S 350 280 400 320 2206A-E13TAG2 JDG314D HCI444FS 6 12.5 130*157 197
27 GDP400*S 400 320 450 360 2206C-E14TAG3 JDG314E HCI444FS 6 12.5 130*157 201
28 GDP455*S 455 364 500 400 2506C-E15TAG1 JDG354B HCI544C 6 15.0 137*171 216
29 GDP500*S 500 400 550 440 2506C-E15TAG2 JDG354C HCI544D 6 15.0 137*171 211
30 GDP600*S 600 480 660 528 2806A-E18TAG1A JDG354D HCI544E 6 18.1 145*183 203
31 GDP600*S 600 480 660 560 2806C-E18TAG3 JDG354D HCI544E 6 18.1 145*183 202
32 GDP650*S 650 520 700 640 2806A-E18TAG2 JDG354E HCI544F 6 18.1 145*183 202
33 GDP730*S 730 584 800 720 4006-23TAG2A JDG404B LV634B 6 22.9 160*190 209
34 GDP800*S 800 640 900 828 4006-23TAG3A JDG404C HCI634G 6 22.9 160*190 210
35 GDP940*S 940 752 1035 828 4008TAG2A JDG404E HCI634H 8 30.6 160*190 202
36 GDP1020*S 1020 816 1120 896 4008TAG2A JDG404F HCI634J 8 30.6 160*190 202
37 GDP1250*S 1250 1000 1375 1100 4012-46TWG2A JDG404G PI734A 12 45.8 160*190 212
38 GDP1360*S 1360 1088 1500 1200 4012-46TWG3A * PI734B 12 45.8 160*190 212
39 GDP1500*S 1500 1200 1650 1320 4012-46TAG2A * PI734C 12 45.8 160*190 200
40 GDP1650*S 1650 1320 1820 1456 4012-46TAG3A * PI734D 12 45.8 160*190 200
41 GDP1825*S 1825 1460 2000 1600 4016TAG1A * PI734E 16 61.1 160*190 205
42 GDP2000*S 2000 1600 2200 1760 4016TAG2A * PI734F 16 61.1 160*190 208
Contact: Ms Vicki Yuan
Tel: 86 514 80915716

Contact us if you need more details on Diesel Generator Set for Railway. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 200kVA Perkin Diesel Generator Set for Railway、160kw/200kVA Perkin Diesel Generator Set for Ra. If these products fail to match your need, please contact us and we would like to provide relevant information.